GT15高壓繼電器
contact &relay ratings units gt15
	contact form c
	contact arrangement spdt
	voltage,test max.,contacts&tobase
	(15μaleakage max., dc or60hz) kv peak 28
	voltage,operating max.,contacts&tobase
(15μa leakage max.) 
	dc or 60hz kv peak 25
	2.5mhz kv peak —
	16mhz kv peak —
	32mhz kv peak —
	current,continuous carry max 
	dc or 60hz amps 18
	2.5mhz amps —
	16mhz amps —
	32mhz amps —
	coil hi-pot(v rms,60hz) v 500
	capacitance 
 across open contacts pf —
 contacts to ground pf —
	resistance,contact max @ 1a,28vdc ohms 0.1
	operate time ms 15
	release time ms 15
	life,mechanical cycles 1million
	weight,nominal g(oz) 120(4)
	vibration,operating,sine(55-500 hz peak) g`s 10
	shock,operating,1/2 sine 11ms(peak) g`s 20
	temperature ambient operating ℃ -55 to +125
coil ratings
	
		nominal,volts dc 12 26.5 115
	
		pick-up,volts dc,max. 9 18 90
	
		drop-out,volts dc .5-5 1-10 5-55
	
		coil resistance
	
		(ohms±10%) 30 125 2000
order the relay with the coil voltage in the part number as shown above. the coil voltage will appear on the coil plate near the coil terminals rather than in the p/n on the relay.